Skip to content
Last updated

Service Test Outcome

Once the tenant has successfully submitted a service test request and the test has been completed by the supplier, the tenant will receive the results via a KCI. Examples of these KCI's can be found here. The below table details the possible results from the service test and if a service problem can be raised. Where a service problem can be raised, this will be valid for 2 hours. After this point a new service test must be carried out before a service problem can be raised. Some results will not allow a service problem to be raised.

Please note: It is currently not possible to raise a service problem if the test outcome is 'GREEN'.

Test OutcomeCodeDescriptionRaise Problem?
REDPOTENTIAL_BRAS_PROFILE_MISMATCHThe service test has identified a potential BRAS profile mismatch. Service problem may be raised to the supplier to investigate further, once end user checks have been completed.Yes
REDSTALE_PPP_SESSIONThe service test has identified a potential stale PPP session. Service problem may be raised to the supplier to investigate further, once end user checks have been completed.Yes
REDPERFORMANCE_BOTTLENECKThe service test has detected a potential performance bottleneck currently being worked on by the supplier. Service problem may be raised to the supplier to get updates on resolution.Yes
REDDAMAGED_CPEThe tenant has reported damaged CPE. Service problem may be raised to the supplier for further investigation, once end user checks have been completed.Yes
REDMULTICAST_CONFIGURATION_ISSUEThe service test has detected a potential issue with the configuration of Multicast. Service problem may be raised to the supplier for further investigation, once end user checks have been completed.Yes
REDPOTENTIAL_TV_CONNECT_ISSUEThe service test has detected a potential issue with the TV Connect service. Service problem may be raised to the supplier for further investigation, once end user checks have been completed.Yes
REDKNOWN_INCIDENTThe service is impacted by a known incident <#Incident ID>, and is anticipated to be resolved by <#Estimated Completion Date>. Please rerun the service test after the incident has been resolved.No
REDNETWORK_NODE_ISSUEThe service test has detected a high VLAN utilisation reaching Red levels. Please wait until VLAN update is complete before retesting. This is anticipated to be around <#actual date/#PEW End Date>Yes
REDHIGH_VLAN_UTILISATIONThe service test has detected a high VLAN utilisation reaching Red levels. Please wait until VLAN update is complete before retesting. This is anticipated to be around <#actual date/#PEW End Date>.No
REDNETWORK_NODE_ISSUEThe service test has detected a potential issue with a network node. Please wait until network node update is complete before retesting. This is anticipated to be around <#PEW End Date>No
REDPOTENTIAL_SERVICE_WIRING_ISSUEThe service test has detected a potential issue with the service wiring. Service problem may be raised to the supplier for further investigation, once end user checks have been completed.Yes
REDPOTENTIAL_HIGH_RESISTANCEThe service test has detected a potential high resistance issue near the end user premises. Service problem may be raised to the supplier for further investigation, once end user checks have been completed.Yes
REDEXISTING_INCIDENTThe service is impacted by a known incident <#Incident ID>, and is anticipated to be resolved by <#Estimated Completion Date>. Please rerun the service test after the incident has been resolved.No
AMBERINSUFFICIENT_DATAInsufficient data available from the service-test to determine an accurate result. Problem may be raised to the supplier to investigate further, once end user checks have been completed.Yes
AMBERPOTENTIAL_LTVN_CONFIGURATION_ISSUEA possible LTVN configuration issue has been identified. Service problem may be raised to the supplier to investigate further, once end user checks have been completed.Yes
AMBERONT_SERIAL_NUMBERService Test has determined a potential fault with the ONT UNI Port <#ONT Serial Number>. Please check the Customers ONT Serial Number for variation and rerun the service test.No
AMBERPOTENTIAL_HIGH_RESISTANCEThe service test has detected a potential high resistance issue near the end user premises, but no network fault detected. Service problem may be raised to the supplier for further investigation, once end user checks have been completed.Yes
AMBERHIGH_VLAN_UTILISATIONThe service test has detected a high VLAN utilisation reaching Amber levels, and end user may experience problems at peak times. The supplier is working on a confirmed date when the issue will be resolved.No
AMBEROUTCOME_UNKNOWNThe Outcome Id returned from the Supplier is not known to the Fibre Cafe. Please review the OutcomeText field for additional details.Yes
GREENMODEM_NOT_CONNECTEDTests indicate the modem is not connected or not powered up. Please ensure the modem is powered up and rerun the service testNo
GREENSHORT_PPP_SESSIONSThe end user appears to be experiencing a large number of short PPP sessions. Recommended end-user checks are performed against PC set-up, drivers & application versions.No
GREENREMOVE_VRIThe service test has detected an issue with the Voice Re-Injection (VRI) within the end user configuration. Please ensure VRI is isolated and rerun the service testNo
GREENNO_PPP_SESSIONThe end user does not have a working PPP session. Recommend end-user checks are performed against PC set-up, drivers & application versions.No
GREENNO_FAULT_FOUNDThe service test has not identified a fault on the supplier network. Please review all end user and tenant related checks.No
GREENHIGH_UTILISATIONThe service test has detected a high end user utilisation of the service reaching acceptable limits. Recommended end-user checks are performed against PC set-up, drivers & application versions and rerun the service test.No
GREENHIGH_TV_CONNECT_UTILISATIONThe service test has not identifier a TV Connect fault on the supplier network. Please review all end user and tenant related checks.No
GREENNO_TV_CONNECT_ISSUEThe service test has not identifier a TV Connect fault on the supplier network. Please review all end user and tenant related checks.No
GREENNON_INTRUSIVE_TESTNo fault identified as part of a non-intrusive service test. Please execute an intrusive service test to determine next actions.No
GREENMODEM_NOT_IN_SYNCThe service test indicates the modem is not in sync with the service. This is normally a result of incompatible modem or double filtering. Please validate suitability of modem and repeat end user checks.No
GREENPOTENTIAL_IN_HOME_ISSUEThe service test has detected a potential home environment resistance issue at the end user premises, but no network fault detected. Recommended end-user checks are performed against PC set-up, drivers & application versions.No
UNAVAILABLEFAILED_VRIThe service test has failed to execute on the supplier side, and Voice Re-Injection (VRI) has been detected. Please ensure VRI is isolated and rerun the service testNo
UNAVAILABLEFAILED_TO_EXECUTEThe service test has failed to execute on the supplier side. Service problem may be raised to the supplier for further investigation, once end user checks have been completed.Yes
FAILEDINVALID_REQUESTThe request is not validNo
FAILEDOUTCOME_UNKNOWNThe error code returned from the Supplier is not known to the Fibre Cafe. Please review the OutcomeText field for additional details.No
FAILEDSERVICE_TEST_NOT_SUPPORTEDService test functionality is not supported for this supplierNo